Commercial Structured Cabling in San Francisco CA – #1 C7 Licensed Contractor

Commercial Structured Cabling in San Francisco CA

We install commercial structured cabling for multi-floor offices, multi-tenant towers, labs and warehouses, connecting the building entrance, MDF and every IDF with certified fiber backbone and Cat6A horizontal cabling.

Looking for commercial structured cabling in San Francisco CA? Our C-7 licensed crews handle the parts of a building-wide system that smaller jobs never touch: riser fiber between floors, demarc extensions from the carrier’s point of entry, landlord base-building standards, and cleanup of abandoned cable left by past tenants.

Wiring a full floor, a whole building or a campus? Get a site walk and itemized quote. Call (628) 215-7235.

Request a quote

What Our Commercial Cabling Covers

Commercial projects add layers that a single-suite install doesn’t have: shared risers, multiple telecom rooms, carrier coordination and building rules. Here’s what we take on.

  • Riser and backbone cabling

    Fiber and copper backbones run vertically through building risers, connecting the MDF to an IDF on every floor. We pull OM4 multimode or OS2 single-mode fiber in innerduct, firestop every sleeve, and leave spare strands for future tenants.

    • OS2 / OM4 Fiber
    • MTP/MPO Trunks
    • Riser Sleeves
    • Firestopping
  • Multi-floor horizontal data cabling

    Hundreds of Cat6A drops per floor, routed on ladder rack and J-hooks, terminated in high-density patch panels and labeled by floor, room, rack and port.

    • Cat6A
    • High-Density Panels
    • Ladder Rack
    • TIA-606 Labels
  • Building entrance and demarc extension

    We extend carrier circuits from the building’s minimum point of entry (MPOE) to your MDF, coordinating with ISPs and the building engineer on the route.

    • MPOE
    • Demarc Extension
    • Carrier Coordination
    • Entrance Conduit
  • Multi-tenant and base-building standards

    Commercial landlords set rules for riser space, cable types and labeling. We follow each building’s base-building standard and submit as-builts to property management at closeout.

    • Landlord Standards
    • Riser Allocation
    • As-Builts
    • Property Management
  • Campus and building-to-building links

    Outside plant fiber between buildings on a campus or across a business park, using armored or indoor/outdoor cable rated for conduit and direct burial.

    • OSP Fiber
    • Armored Cable
    • Conduit
    • Campus Backbone
  • Cable abatement and cleanup

    California code requires abandoned cable to be removed. We identify, tag and pull dead cable from ceilings and risers so your space passes inspection and has room for growth.

    • Abandoned Cable
    • Riser Cleanup
    • Code Compliance
    • Ceiling Clearing

Commercial Cable Ratings & Specifications

In a commercial building, the cable jacket matters as much as the category. Cable that runs through air-handling ceilings must be plenum-rated, cable in vertical risers must be riser-rated, and cable between buildings must be rated for outdoor conduit. Installing the wrong rating fails inspection and has to be pulled out, so we specify the jacket for every pathway before ordering material.

Cable jacket ratings used in commercial structured cabling and where each is installed
RatingCable typeWhere it’s installedCode reference
CMP (plenum)Cat6 / Cat6A copperAir-handling ceilings and raised floorsNEC 800.179(A)
CMR (riser)Cat6 / Cat6A copperVertical shafts between floorsNEC 800.179(B)
OFNP (plenum)Non-conductive fiberPlenum ceilings, horizontal fiber runsNEC 770.179(A)
OFNR (riser)Non-conductive fiberRiser backbone between MDF and IDFsNEC 770.179(B)
Indoor/outdoor or OSPArmored or gel-free fiberUnderground conduit between buildingsNEC 770.48 (50 ft entrance limit)

Commercial buildings we wire

  • Class A office towers
  • Multi-tenant office buildings
  • Corporate headquarters
  • Life science and lab buildings
  • Warehouses and distribution centers
  • Hotels and hospitality
  • Medical office buildings
  • Business parks and campuses
Vertical riser shaft in a high-rise building used for backbone cabling between floors
Riser shaft in a 20-story office tower: a 48-strand OM4 OFNR backbone in innerduct and CMR-rated Cat6A bundles pass through firestopped 4-inch sleeves, with two spare sleeves left open on each floor for future tenants.

Where We Build Commercial Cabling Infrastructure

East Cut and Transbay towers

Multi-floor buildouts in new high-rises around the Salesforce Transit Center, where tenants share riser capacity and every floor ties into a central MDF.

Mission Bay lab campuses

Multi-building life science campuses with outside plant fiber between buildings and separate backbones for lab systems and corporate networks.

Union Square hotels

Guest-room and back-of-house cabling across dozens of floors, scheduled floor by floor so rooms come back into service quickly.

Bayview and Dogpatch warehouses

Distribution centers and flex industrial space where long horizontal runs require IDFs placed to stay within the 90 m limit.

How We Run a Commercial Cabling Project

  1. Building survey

    We meet the building engineer, inspect the MPOE, risers and telecom rooms, and confirm the landlord’s base-building standards.

  2. Design and submittals

    You get a backbone diagram, drop counts, rack elevations and cable specs, ready to submit to property management for approval.

  3. Scheduling and access

    We book freight elevators, provide certificates of insurance, and schedule noisy or ceiling work after hours to suit occupied buildings.

  4. Backbone, then horizontal

    Riser fiber and telecom rooms go in first, then horizontal cabling floor by floor, so each floor can go live as it’s finished.

  5. Certification and closeout

    Every link is tested, and as-builts go to both your IT team and property management.

Testing & Documentation for Commercial Buildings

Copper permanent links are certified to TIA-568.2-D, and every backbone strand gets Tier 1 loss testing and a Tier 2 OTDR trace. Reports are organized by floor and telecom room, and labeling follows TIA-606 so future tenants and contractors can read your system without guessing.

Fiber backbone test summary showing OM4 link loss results
Backbone test summary for a 12-floor office building: 576 OM4 strands tested, average link loss of 0.9 dB against a 2.6 dB budget for 10GBASE-SR, with no splice over 0.15 dB.

Commercial work often pairs with these related scopes. See our main structured cabling page for the full overview.

Commercial Structured Cabling Service Area

We wire commercial buildings in every neighborhood of the city, plus these Peninsula, East Bay and Marin cities:

See every location on our service area page.

Request a Commercial Cabling Quote

Send floor plans, drop counts or your landlord’s base-building standard, and we’ll schedule a site walk and return an itemized quote, usually within two business days.