OTDR Testing & Certification in San Francisco CA
We certify single-mode and multimode fiber with Tier 1 optical loss testing and Tier 2 OTDR traces, measuring every strand against its loss budget and mapping every connector, splice and fault along the link.
Need OTDR testing & certification in San Francisco CA? Our technicians test new fiber before handoff, audit backbones you inherited with a lease, and locate breaks after construction damage or outages. You get bidirectional traces, event tables and exported reports that qualify the link for manufacturer warranties and prove it will carry 10, 40 or 100 Gbps.
Need fiber certified for a warranty, a handoff or a fault you can’t find? Call (628) 215-7235.
Request a quoteWhat an OTDR Trace Shows
An optical time-domain reflectometer sends pulses of light down the fiber and measures what reflects back over time. The result is a trace: a graph of loss along the full length of the link, with each event marked by its distance from the tester. Where a power meter only tells you total loss, an OTDR tells you exactly where that loss happens.
- ConnectorsShow as a reflective spike. We measure loss and reflectance at every mated pair and flag dirty or damaged end faces.
- Fusion splicesShow as a small step with no spike. Bidirectional testing averages out false gains so you see the true splice loss.
- MacrobendsShow as extra loss that grows at 1550 nm compared with 1310 nm, pointing to a tight bend or crushed cable.
- Breaks and faultsShow as a sudden drop to noise. The trace gives the distance to the fault, so repairs start in the right place.
- Fiber lengthMeasured from launch to end, confirming the link matches the design and the as-built drawings.
- AttenuationLoss per kilometer along each section, confirming the glass itself meets its rated performance.
Tier 1 vs Tier 2 Certification
Industry standards define two levels of fiber certification. Tier 1 is required for every link. Tier 2 adds the OTDR trace and is what most manufacturers, general contractors and building owners ask for on backbones and campus links. We run both on every strand unless your project calls for Tier 1 only.
| Level | Equipment | What it measures | What it proves | Reference |
|---|---|---|---|---|
| Tier 1 (basic) | Optical loss test set (light source and power meter) | Total insertion loss, length, polarity | The link is within its loss budget end to end | TIA-568.3-D, TIA-526-14 / -7 |
| Tier 2 (extended) | OTDR with launch and receive fibers | Loss and reflectance of each connector and splice, attenuation, distance to every event | Every component was installed correctly, not just the total | TIA-568.3-D, ISO/IEC 14763-3 |
Loss Budgets & Pass/Fail Limits
Every link is judged against a loss budget: the maximum loss allowed for its length, connectors and splices. We calculate it from the standard limits below, then check it against the tighter limit of the application you plan to run, such as 10GBASE-SR or 100GBASE-SR4.
| Component | Maximum allowance | Typical result we see |
|---|---|---|
| Multimode fiber at 850 nm | 3.5 dB per km | 2.3–3.0 dB per km |
| Single-mode fiber, inside plant | 1.0 dB per km at 1310 / 1550 nm | 0.3–0.4 dB per km |
| Mated connector pair | 0.75 dB | 0.2–0.5 dB |
| Fusion splice | 0.3 dB | Under 0.1 dB |
| 10GBASE-SR on OM4 (application) | 2.9 dB channel loss, up to 400 m | Checked against the link total |
| 100GBASE-SR4 on OM4 (application) | 1.9 dB channel loss, up to 150 m | Checked against the link total |
Example: a 150 m OM4 backbone with two connector pairs and two splices.
Fiber 0.15 km × 3.5 dB = 0.53 dB, connectors 2 × 0.75 dB = 1.50 dB, splices 2 × 0.3 dB = 0.60 dB.
Standard budget: 2.63 dB. To run 100GBASE-SR4, the same link must also measure under 1.9 dB.
When to Schedule OTDR Testing
- New backbone and riser installs
- Campus and building-to-building links
- Manufacturer warranty registration
- Acceptance testing for general contractors
- Move-in audits of existing fiber
- Upgrades to 40 or 100 Gbps
- Outages and intermittent links
- Damage after construction or excavation
- Carrier and demarc handoffs
- Documentation for audits
Testing work around the Bay Area
Financial District riser acceptance
Tier 2 certification of new OM4 and OS2 backbones in Market Street towers, with reports handed to the general contractor and property management at closeout.
Mission Bay campus fault location
Tracing a dark single-mode link between lab buildings to a crushed section of conduit, measured to within a few meters before excavation.
Embarcadero pier backbones
Testing long fiber runs in converted waterfront piers, where tight bends around old timber framing show up clearly at 1550 nm.
SoMa server room upgrades
Re-certifying existing OM3 and OM4 trunks against the tighter 100GBASE-SR4 limit before a client moves to 100 Gbps switch uplinks.
Our Testing Process, From Site Survey to Reports
Test plan and loss budgets
We confirm fiber type, strand count and link lengths, then set wavelengths (850/1300 nm for multimode, 1310/1550 nm for single-mode) and calculate each link’s budget.
Clean, inspect and reference
Every connector end face is inspected with a scope and cleaned, and the loss test set is referenced with the one-jumper method.
Tier 1 loss testing
Each strand’s total loss, length and polarity are measured and compared against its budget.
Bidirectional OTDR traces
Using launch and receive fibers, we trace every strand from both ends so the first and last connectors are measured and splice readings are accurate.
Fix and retest
High-loss connectors are cleaned or re-terminated, bad splices are redone, and the strand is retested until it passes.
Reports
You receive PDF summaries and native trace files for every strand, organized by enclosure and labeled to match your strand map.
Related Fiber Optic Services
Testing is the last step of every fiber job, and it often uncovers work for these related services. See our main fiber optic cabling page for the full overview, or our copper testing and certification page for Cat6 and Cat6A.
- Fiber Optic Installation: Backbone, riser and outside plant fiber pulled and protected for testing.
- Fiber Optic Splicing: Fusion splicing for pigtails, entrances and repairs found during testing.
- Fiber Termination: LC, SC and MTP/MPO connectors terminated and mounted in labeled enclosures.
OTDR Testing Service Area
We test fiber in every neighborhood of the city, plus these Peninsula, East Bay and Marin cities:
- Daly City, CA
- Tiburon, CA
- Alameda, CA
- Oakland, CA
- South San Francisco, CA
- San Bruno, CA
- Albany, CA
- Berkeley, CA
- Piedmont, CA
- Mill Valley, CA
See every location on our service area page.
Request an OTDR Testing Quote
Tell us how many strands, the fiber type, approximate link lengths and whether the fiber is new or existing, and we’ll return an itemized quote, usually within two business days.
San Francisco Telecom TechsOne Beach St, San Francisco, CA 94133
Phone: (628) 215-7235
Email: [email protected]
Get every fiber strand tested, documented and warranty-ready.
Request a quote