We wire every piece of a controlled door: the card reader, the electric lock, the door contact, the request-to-exit device and the controller that ties them together, all labeled, tested and ready for your security integrator.

Need access control wiring in San Francisco CA? Our C-7 licensed technicians run reader and lock cable from each door to its controller, install strikes, mag locks, contacts and REX devices, size lock power so doors work reliably, and tie magnetic locks into the fire alarm. Your integrator can then program credentials on day one instead of troubleshooting wiring.

Adding badge readers or replacing keys with card access? Get a walkthrough and itemized quote. Call (628) 215-7235.

Request a quote

What We Wire at Every Controlled Door

A controlled door is more than a card reader. Each one needs four or five devices wired back to a controller, and every one of them has to work for the door to be secure and code compliant.

  • Card reader wiring

    Shielded cable from every reader to its door controller, run for Wiegand or the newer, encrypted OSDP protocol, with a service loop at the frame.

    • Wiegand
    • OSDP
    • Shielded Cable
    • Mobile Credentials
  • Electric strikes and mag locks

    Lock power wiring for electric strikes, magnetic locks and electrified hardware, sized so voltage stays in spec at the door.

    • Electric Strikes
    • Mag Locks
    • Electrified Hardware
    • Power Transfer Hinges
  • Door contacts and REX devices

    Door position switches that report forced and propped doors, and request-to-exit sensors or push buttons for free egress.

    • Door Position Switches
    • Motion REX
    • Push-to-Exit
    • Held-Open Alerts
  • Door controllers and panels

    IP door controllers and multi-door panels mounted in the IDF or above the ceiling, powered by PoE or a dedicated supply.

    • IP Controllers
    • Multi-Door Panels
    • PoE Powered
    • Lockable Enclosures
  • Power supplies and battery backup

    Lock power supplies with battery backup so doors behave predictably during a power outage, set fail-safe or fail-secure per door.

    • Lock Power Supplies
    • Battery Backup
    • Fail-Safe / Fail-Secure
    • Fused Outputs
  • Fire alarm release

    Magnetic locks and electrified egress doors tied into the fire alarm so they release automatically in an emergency, as code requires.

    • Fire Alarm Interface
    • Egress Release
    • Code Compliance
    • Inspection Ready

Door Wiring and Access Cabling Requirements

These are the cable types we typically run for each component. Exact conductor counts and gauges depend on the reader, lock and controller models, so we confirm them against the manufacturer’s wiring diagrams during design.

Typical cabling for each access control door component
Door componentTypical cableConnects toNotes
Card reader (Wiegand)22 AWG, 6-conductor shieldedDoor controllerCommon on older and budget systems
Card reader (OSDP)22 AWG shielded twisted pair plus power pairDoor controller (RS-485)Encrypted, supervised, supports longer runs
Electric strike or mag lock18 AWG, 2-conductor (16 AWG on long runs)Lock power supply via controller relaySized for voltage drop at the door
Door position switch22 AWG, 2-conductorDoor controller inputReports forced and held-open doors
Request-to-exit (REX)22 AWG, 4-conductorDoor controller input and lock circuitMotion sensor or push button
Composite access cableReader, lock, contact and REX in one plenum jacketDoor controllerOne pull per door, faster and neater
IP door controllerCat6Network switch, access server or cloudOften powered by 802.3at PoE

How we wire each door into your structured cabling

Every door gets a home run from the frame to its controller, usually in composite plenum cable so one pull carries the reader, lock, contact and REX conductors. We leave a service loop above the door, use power transfer hinges or door loops for locks mounted in the door leaf, and run surface raceway on glass storefronts where there’s no wall to hide cable in. Lock power is calculated for every run so a 12 or 24 VDC lock still gets the voltage it needs at the end of a long cable. Each mag lock is set fail-safe, paired with a motion REX and a push-to-exit button, and wired to release on fire alarm, as the California Building Code requires.

Controlled office door with a card reader, magnetic lock and request-to-exit sensor
A fully wired controlled door: OSDP reader, 1,200 lb fail-safe mag lock, recessed door position switch, motion REX and push-to-exit button, all on one composite cable home-run to a two-door IP controller in the IDF.

Access Control Projects Across San Francisco

Mission Bay lab suites

Readers and electric locks on labs, freezer rooms and restricted areas, with door contacts that log every opening for compliance.

Financial District offices

Suite entries and server rooms wired to work with the building’s lobby system, so tenants carry one badge.

Union Square retail

Card access on stockrooms, cash offices and staff entrances, wired neatly through tight storefront framing.

SoMa coworking spaces

Mobile-credential readers on front doors and private offices, with IP controllers managed from the cloud.

Our Access Control Wiring Process

  1. Door survey

    We check each door’s frame, hardware, swing and egress needs, and mark controller and power supply locations.

  2. Design with your integrator

    We confirm reader, lock and controller models with your security integrator, then plan cable types and lock power.

  3. Rough-in

    Composite or individual cables are home-run from each door to the controller and labeled at both ends.

  4. Trim-out and device installation

    Readers, locks, contacts and REX devices are mounted and terminated, and power supplies and controllers installed.

  5. Door-by-door testing

    We test every read, unlock, forced-door and held-open alarm, REX release, fire alarm release and battery backup.

Door wiring is one part of a complete security setup. See our main security infrastructure page for the full overview, or our intercom page for visitor entry at the same doors.

Access Control Wiring Service Area

We wire controlled doors in every neighborhood of the city, plus these Peninsula, East Bay and Marin cities:

See every location on our service area page.

Request an Access Control Wiring Quote

Tell us how many doors you want to control, the type of doors and whether you already have a reader brand in mind, and we’ll schedule a walkthrough and return an itemized quote, usually within two business days.

San Francisco Telecom Techs
One Beach St, San Francisco, CA 94133
Phone: (628) 215-7235
Email: [email protected]

Get every controlled door wired, tested and ready for credentials.

Request a quote

Send us your project details